APX-5200B-1
12Bit/1GSps 2Ch(Sync) hi-speed sampling Digitizer
Model | APX-5200B-1 |
Input channel | Single end 2 ch (interleaved: single end 1 ch) |
resolution | 12bit |
Sampling clock | Frequency range: 150 MSps to 1 GSps (interleave: 2 GSps) Frequency Resolution: Individual (* 1, * 2) |
Sampling time | 1 ns (min) (at interleave: 0.5 ns (min)) |
Number of samples | 2 G words / 2 ch, 4 G words / 1 ch |
Input range | ±0.5V |
Input impedance | 50Ω |
Analog band | 900MHz(-3dB) |
Input connector | SMA connector |
Trigger | External trigger / analog trigger / soft trigger |
External clock | Input (when PPL is used): 5 MHz to 100 MHz Input (direct input): 500 MHz to 1000 MHz |
External trigger | Input: LVTTL edge detection (invertible) |
SNR | 59.41dB |
SINAD | 59.17dB |
ENOB | 9.53bit |
SFDR | 72.18dB |
memory | DDR3 – SDRAM (8 GB) |
FPGA | 5 SGXMA 3 K 1 F 40 C 2 N (manufactured by ALTERA) Trigger type: Internal trigger (analog trigger), external trigger, soft trigger Analog trigger: edge · pulse trigger position: pre / post delay |
General purpose AO | Number of outputs: 2 ch Resolution: 16 bits Output range: -4 V to +4 V |
System bus | PCI Express 2.0 (Gen 2) 5.0 GT / s × 8 |
Power supply | + 12 V / 3.3 A (39.6 W) |
Operating environment | Temperature 0 to 45 ° C, humidity 35% to 85% (no condensation) |
Size | 212.5 mm × 111.15 mm, panel width 20 mm (not including projections) |
weight | |
Supported OS | Windows 7/8/10 compatible with 32 bit / 64 bit each |
Software development kit | Windows: AWP-ADCSDK2-01 Linux: ALP-5200-01 |
Evaluation tool | AWP-ADCTOOL-01 |
LabView VI Sample | AWP-ADCLV-01 |
Environmental response | RoHS |
* 1: On board, default clock is set as 25MHz
* 2: There is a limit to the sample rate that can be set※ This product cannot be recognized correctly by some Workstation (PC) equipped with Xeon E5 V3 series processor.
※ For details please contact us: sales@aval-global.comNotes)
– The specifications and appearance stated are subject to change without notice.
– Power consumption does not include inrush current.
– In order to use the product correctly, be sure to read the instruction manual before using the product. Also, use the product under the conditions applicable to your product warranty.
* 2: There is a limit to the sample rate that can be set※ This product cannot be recognized correctly by some Workstation (PC) equipped with Xeon E5 V3 series processor.
※ For details please contact us: sales@aval-global.comNotes)
– The specifications and appearance stated are subject to change without notice.
– Power consumption does not include inrush current.
– In order to use the product correctly, be sure to read the instruction manual before using the product. Also, use the product under the conditions applicable to your product warranty.
1) Medical Equipment
2) Measurement Equipment
3) 3D Measuring Intrusment
4) Big Data Log System
5) Measurement Equipment
Express Converter series software tool
– AWP-ADCTOOL-01: Evaluation tool for A / D
– AWP-ADCLV-01: VI library for A / D LabVIEW
– AWP-ADCTOOL-01: Evaluation tool for A / D
– AWP-ADCLV-01: VI library for A / D LabVIEW
For FPX customization of APX – 5200 please, contact US.